Zero-trust zone. seib Cowork, fully isolated for internal use: the model, its knowledge and its rules inside your walls.
- Internet route
- None, by design
- Model
- seib-1, on your GPU
- Serves
- One RTX PRO 6000 Blackwell: about 55 users at 32k, 15 at 128k (estimate)
One zone. Everything inside it.
The seib model and embeddings on your GPU server, knowledge and policy on your application server, the coworker on each desk, your systems behind one connector bus. The internet stays outside the wall.
Nothing is trusted for being inside.
Zero trust means the network boundary is not the only defence. Inside the zone, every person, request and action is checked on its own.
- 01No route out
- The zone is designed with no route to the internet. The model, the embeddings, the knowledge store and the policy all answer from inside it, so nothing a task reads has anywhere to go.
- 02Every person signs in as themselves
- Each engineer connects to each system with their own account, so every system keeps its own permissions. Connector definitions are shared; credentials never are, and they stay in each workstation's keychain.
- 03The model can't act
- seib-1 only proposes the next step. The desktop checks it against policy and folder limits, shows it, and runs it only if allowed. Every write to another system asks, every time.
- 04Least access by default
- Connectors can be read-only and limited to approved hosts and paths. A desktop's knowledge-base token can search and do nothing else. Members may tighten their settings, never loosen them.
- 05Content is not instruction
- Documents are treated as material, not commands. A command that matches text from a document just read is flagged and always asks; hidden and right-to-left characters are made visible.
- 06Everything leaves a record
- Each task keeps a hash-chained audit trail of the request, every action and who allowed it, so any edit or deletion shows. It exports as CSV or JSON Lines.
One GPU. Up to 55 people working at once.
seib-1 is sized to run on hardware an organisation can buy and keep in its own rack. One NVIDIA RTX PRO 6000 Blackwell holds the model at 4-bit with about 55 concurrent users at a typical 32,000-token context, or 15 at the full 128,000.
What runs where
- GPU server
seib-1, the embedding model, and the vision model that reads scanned pages
One NVIDIA RTX PRO 6000 Blackwell, 96 GB
- Application server
Accounts and policy, the dashboard, the knowledge store (Qdrant)
A standard rack server; no GPU
- Workstations
seib Cowork on each desk: approvals, undo, encrypted task history and audit
The macOS and Windows machines people already use
The arithmetic
- Card
- RTX PRO 6000 Blackwell, 96 GB
- Usable at 90%
- about 86 GB
- seib-1 weights, 4-bit (NVFP4)
- 16.5 GB, about 1–3% below FP8
- Serving framework
- about 2 GB
- Left for working memory
- about 68 GB
- One task at 32k tokens
- 1.0 GB cache + 0.15 GB state
- One task at 128k tokens
- 4.2 GB cache + 0.15 GB state
- Concurrent users, 32k each
- about 55
- Concurrent users, 128k each
- 15
With FP8 weights instead, the same card holds about 45 users at 32k, or 12 at 128k. An estimate from the memory figures in the seib-1 technical report, not a measurement. Most tasks use far less than the full context, which leaves headroom; load-test before sizing a site.
What ships today, and what is designed.
The controls on each desk ship today in both editions. The fully isolated zone is the on-premises edition's design, built with pilot partners.
Today
- Policy set centrally and enforced on every desk, even offline
- Approvals for every edit, command and external write; undo for every edit
- Credentials in each workstation's keychain, never sent anywhere
- Hash-chained audit trail, exported as CSV or JSON Lines
- Strict mode: commands in a sandbox limited to the task's folder, optionally offline
- The server bundle for knowledge bases: Qdrant and the dashboard, with Docker Compose
Designed
- seib-1 served from your own GPU, with no route to the internet
- Embeddings and page reading on the same server
- The whole zone installable without any connection to seib
Not yet
- Directory single sign-on
- Audit export into a SIEM
Request pilot access.
Not a waitlist. Tell us the problem and we’ll tell you honestly whether seib is ready for it.
- 1A person reads your request and replies within a few business days.
- 2A short call about the line, the toolchain and what's slow today.
- 3A Cowork pilot starts with one team, read-only connectors and two or three knowledge bases.